Efficiency and replacement economics

Electric furnace efficiency

Compare fuel costs for the same delivered heat.

Entries are saved on this device for this browser tab. Reset clears them.

Equal-heat fuel cost comparison
1. Demand and source
2. Performance (required)

COP must describe the stated period and temperature conditions. Zero backup is a declared scenario, not a verified promise for your house.

3. Rates (editable defaults)

EIA 2025 US residential averages: electricity 17.30 cents/kWh; natural gas $15.34 per thousand cubic feet. Gas reference converts to about $1.4807/therm using EIA approximate 1,036 BTU/ft³. National references, not your local tariff; replace with your bill. Checked October 14, 2026. Electricity source; gas source; unit conversion.

Result not yet calculated

Enter the required data. Unknown assumptions do not become guessed values.

Method v1.0. Checked October 14, 2026. Sources and limits.

A residential room in natural window light
Sections8

Electric furnace efficiency describes energy conversion at the resistance heater, not the cost of electricity or the heat reaching each room. An electric furnace and a heat pump both use electricity but produce heat in different ways. Use equal useful heat and a stated rate to compare their running costs.

Resistance elements convert their power input into heat at the point of use. The duct network and other power uses sit outside that simple boundary. A heat pump moves heat and uses COP to describe its performance at stated terms. High conversion rating does not guarantee a low bill. Keep tariffs, heat demand and backup heat bases visible in any comparison.

Electric furnace efficiency: resistance conversion

Carrier's furnace guide explains the resistance-heat boundary. DOE's heat pump purchasing guide uses a different heat-pump rating method. Those systems should not share one marketing rating.

Heating system What it does Performance record
Resistance furnace Produces heat at electric elements Heat output, electrical input and delivery scope
Heat pump Transfers heat from a source COP and output at stated conditions
Heat pump with strips Uses both processes Backup share and control assumptions
Combustion furnace Converts fuel heat Full-model AFUE plus auxiliary electricity

Heat delivery and duct losses

Heat at an element is not the same as heat at every room. The blower and duct network carry that heat. Their state and layout matter to the system.

Do not assign a fixed duct-loss percent without evidence. Keep the actual network record beside the unit data. ACCA Manual D covers duct design. Manual J covers the room loads it must serve.

The duct cost guide helps price defined work. A new heater does not prove the ducts need no changes. Nor does a cold room prove the electric elements are failing to convert energy.

Electric furnace efficiency versus heat-pump COP

COP is heat delivered divided by power energy consumed, in matching units. A heat pump can deliver more heat than the power input alone because it transfers heat from outside the unit boundary.

That does not violate energy accounting. The source contributes heat. A resistance heater uses a different process. Keep both the input energy and supplied heat visible in the comparison.

Comparison field Resistance heat Heat pump
Delivered heat need Same declared demand Same declared demand
Electrical use Heat demand converted to kWh Heat demand divided by COP
Outdoor conditions Affect building demand Affect demand and pump performance
Backup heat Main process is resistance Share must be stated where used
Rate Actual or labelled national reference Same rate basis for equal comparison

Do not infer COP from a SEER2 cooling label. Keep the actual heating terms and performance source. A seasonal average and a design-temperature value answer different questions.

Equal-heat operating-cost worksheet

The tool above compares a heat pump, resistance heat and a gas furnace using the same declared heat demand. It supplies editable national rate references, not a tariff for your address. Demand, AFUE and COP each need a source you state.

The EIA energy-unit table supplies the heat-to-kWh and therm conversions. A heat quantity over a period differs from an hourly load. Do not multiply a peak-load figure by every hour in a year and call it measured yearly use.

Keep fixed service charges and non-heating uses separate. The worksheet prices a variable-energy scenario. It does not deduct a future rebate or change the installed purchase price.

Read marketing claims with a clear boundary

A claim such as “high rating electric heat” can describe element conversion without showing a low cost to run. Ask which units, period and system boundary the claim uses. A percent cannot replace those fields.

If a bid compares resistance heat with a heat pump, record low-temperature output and backup scope too. A high COP at one mild state is not proof of that figure throughout your heating season.

For the purchase decision, see electric furnace installation cost and heat pump versus furnace. Keep installed and running budgets on separate sheets.

Heat at the heater is not a bill

The heater makes heat. The ducts move it. The bill prices the power used over time. Those are three linked records, but they do not say the same thing.

Write down the period first. Then record the heat need and the rate.

If the heat pump shares the job with backup heat, state that share too. Do not put the same power use through COP twice. Known kWh is already input energy, not heat demand. Keep that distinction visible in the worksheet before comparing the costs.

FAQ

Does resistance efficiency prove electricity is cheaper than gas?

No. The price per unit of energy and the heat demand still matter. Gas uses a fuel conversion ratio while resistance heat uses power input. Compare equal useful heat with matching units and stated rates. A high conversion figure alone cannot settle which system has the lower variable cost for your home and period.

Can a heat pump be more than fully efficient?

COP measures heat moved relative to power energy consumed. The source supplies extra heat, so the useful heat can exceed the power input alone. This is a different boundary from element conversion. Use the stated running terms and full performance record rather than treating the figure as a combustion-rating percent for comparison.

Are duct losses included in element conversion?

No. Producing heat at an element and delivering it to rooms are separate stages. Keep blower use and the actual duct network outside the simple element boundary. A high conversion claim does not prove the installed duct network meets every room's load or that all heat arrives where it is needed without loss.

Does the worksheet estimate my actual bill automatically?

No. It uses your declared heat demand and performance figures with editable rate references. The national rates are not your tariff. Fixed charges, other appliance use and unknown other electricity remain outside its variable-energy result. Replace bases with your own sourced records before treating the scenario as a home-specific running-cost comparison.

Verdict: separate electric furnace efficiency from fuel cost

Electric furnace efficiency is one conversion fact. It does not settle installed fit or running cost. Use equal heat and clear rates. Then compare the whole-system options and return to the efficiency parent guide for the rating boundaries.